Fault phenomenon: start, the motor does not rotate
Cause:
1, power failure or power supply fuse blown;
2, the power plug is not inserted, or the power cord is disconnected;
3, the switch contact is poor;
4, desktop mixer cover is not put right cover, safety switch out of contact, circuit no electricity;
5, bearing lack of oil, turn embroidery dead, belt loose or slip;
6. Motor stator is damaged or burned;
7. The overheating protection switch is in open circuit or damaged
Solution:
1, with normal power supply use, replace the appropriate fuse;
2, plug in the power plug, reconnect or replace the power cord;
3. Return to the factory for maintenance;
4, cover the cover, so that the safety switch normal contact;
5, remove rust, oil, replace the belt;
6. Return to the factory for maintenance;
7, with the motor cooling before use, or return to the factory for maintenance
Fault phenomenon: the motor has high heat
Cause:
1, stirred food is too much or too thick, heavy load;
2, the voltage is too high;
3. Overload and timeout;
4. Long running time;
5, bearing oil shortage;
6, motor local short circuit
Solution:
1, appropriate reduction, dilution of food or pay attention to avoid solid food;
2, with normal voltage to use;
3, according to the specification of the weight of use;
4. Control running time not exceeding 20 minutes;
5, appropriate oil injection;
6. Return to the factory for maintenance